Maintenance
28
1
2
3
4
5
6
7
8
9
10
11
4.4.2 Cleaning/replacing the UV low pressure
lamps in the side section
1
2
04011 / 0
Removal
Danger of burns!
Make sure that the UV low pressure lamps have cooled
down.
•
=
Disconnect sunbed and secure against
accidentally being switched on again (refer to
section 4.3).
•
=
Unscrew the screws (1) at the head and foot
ends and carefully fold down the acrylic panel
(2).
04022 / 0
4
3
•
=
Remove the UV low pressure lamps (3) and (4)
and change, cleaning with a damp cloth if
necessary.
Installation
•
=
Insert the UV low pressure lamps with the
lettering towards the foot end and rotate by 90
degrees (1/4 turn) until they catch. The lettering
is on the visible side of the UV low pressure
lamps. Do not align the lamps by the lettering.
•
=
For further assembly proceed in reverse order.