Maintenance
29
1
2
3
4
5
6
7
8
9
10
11
4.4.3 Cleaning/replacing the UV low pressure
lamps in the canopy
01511 / 0
Removal
Danger of burns!
Make sure that the UV low pressure lamps have cooled
down.
•
=
Disconnect sunbed and secure against
accidentally being switched on again (refer to
section 4.3).
Risk of injury from falling acrylic panel!
Hold the acrylic panel securely when opening it.
04014 / 0
4
3
1
2
•
=
Hold the acrylic panel (1) and unscrew the
screws (2) at the head and foot ends with an
Allen key.
•
=
Carefully fold down acrylic panel (1) and place on
the base.
•
=
Remove the UV low pressure lamps (3) and (4)
and change, cleaning with a damp cloth if
necessary.
Installation
•
=
Insert the UV low pressure lamps with the
lettering towards the foot end and rotate by 90
degrees (1/4 turn) until they catch. The lettering
is on the visible side of the UV low pressure
lamps. Do not align the lamps by the lettering.
•
=
For further assembly proceed in reverse order.
Summary of Contents for Classik 475