Maintenance
33
1
2
3
4
5
6
7
8
9
10
11
4.6.2 Cleaning the sieve cylinder and lamellas
1
B
A
04018 / 0
Removal
•
=
Disconnect sunbed and secure against
accidentally being switched on again (refer to
section 4.3).
•
=
Unlock the trough (1) with an Allen key at the
trough lock.
•
=
Fold up the trough (1) together with the sunbed
base.
2
3
1
04025 / 0
•
=
Loosen the screws (1) and lift up the suction pipe
(2).
•
=
Remove and clean the sieve cylinder (3).
04026 / 0
•
=
Remove dirt from the lamellas on the front of the
air conditioner with a vacuum cleaner.
Installation
•
=
Assemble in reverse order.