Crack-Vac Model 100G Manual
Chapter 5 Operating Instructions
©2020 by Crafco, Inc. All Rights Reserved
Operating Instructions 5-14
5.10 Debris Storage Tank
The debris storage tank has a 100-gallon capacity. The tank should be cleaned out daily or before
every use to insure proper air flow through the system.
Step
Action
1
Unlatch the LG 16” manhole cover on the storage tank. Unlatch the 3 cam levers
that do not have the safety catch wire first. Unlatch the cam lever with the safety
wire catch. The safety catch wire will keep the door from opening too quickly. Move
the safety wire catch out of the way and the door will open. See
2
When the door is unlatched, raise the storage tank by using the toggle switch
located in the side frame at the front of the machine. Lifting the toggle switch will
raise the tank to the up position. See
Figure 5-8 Debris Storage Tank Switch
3
Once the dirt, rocks, and other debris have exited the tank, use the toggle switch to
lower the tank back to the down position.
WARNING
Use caution not to pinch any part of the body when lowering the storage tank. Do
not allow bystanders near the machine when lowering the storage tank.
Note:
There is a restricting plug in the return side of the hydraulic line. This plug is a
safety device that prevents the tank from lowering too quickly.
4
When the tank is back in the lowered position, push the door close and latch the
cam lever with the safety ring first, followed by the remaining three.
Cam Lever
Safety Catch
Wire
Table 5-15 Emptying the Debris Storage Tank
Figure 5-7 Debris Storage Tank Door
Summary of Contents for 60800N
Page 1: ...CRACK VAC MODEL 100G Operator Parts Manual 26627N Revision O ...
Page 3: ...Crack Vac Model 100G Manual Revisions Revision Date ...
Page 4: ...CRACK VAC MODEL 100G with COMPRESSOR P N 60900N CRACK VAC MODEL 100G P N 60800N ...
Page 10: ......
Page 12: ......
Page 18: ......
Page 22: ......
Page 40: ......
Page 77: ......
Page 78: ... 2020 Crafco Inc ...