EZ 1000 Series II Melter Part Manual
Chapter 8 Troubleshooting
©2019 by Crafco, Inc. All Rights Reserved………………...………………………………..……………...Troubleshooting 8-3
Step
Possible Cause
If . . .
3
Is there 12Vdc between the positive and
negative battery post? If this check is done
while the engine is running the reading
should be 13.8 volts.
•
Yes, then there should be 12Vdc on the
battery side of the circuit breaker.
•
No, replace battery.
•
NOTE
:
If the reading is less than 13.8 volts
while the engine is running the alternator
needs to be rebuilt or replaced.
4
Find insulated quick connect between green
wire and white wire that goes to burner plug.
Is there 12Vdc between the green wire and a
nearby ground source (black wire)?
•
Yes, go to
•
No, go to step 4a.
4a
Is there 12Vdc between green wire labeled
“GRN-BRNR” on upper terminal blocks and
nearby ground source (black wire)?
•
Yes, check for loose or broken wires
between burner plug and terminal block.
•
No, go to Step 5.
5
Is there 12Vdc between gray wire labeled
“GRY-2” and nearby ground source?
•
Yes, replace terminal block.
•
No, go to Step 5a.
5a
Is there 12Vdc between terminal #7 gray wire
and terminal #5 black wire of the hot oil
PAKSTAT?
•
Yes, check for loose or broken wires
between terminal block and terminal #7 of
the hot oil PAKSTAT.
•
No, go to Step 5b.
5b
Is there 12Vdc between terminal #6 gray wire
and terminal #5 black wire of hot oil
PAKSTAT?
•
Yes, replace hot oil PAKSTAT.
•
No, go to Step 6.
6
Is there 12Vdc between gray wire labeled
“GRY-3” on upper terminal blocks and a
nearby ground source (black wire)?
•
Yes, check for loose or broken wires
between terminal block and terminal #6 of
the hot oil PAKSTAT.
•
No, go to Step 6a.
6a
Is there 12Vdc between gray wire labeled
“GRY-1” on upper terminal blocks and a
nearby ground source (black wire)?
•
Yes, replace terminal block.
•
No, go to Step 7.
7
Is there 12Vdc between terminal #4 gray wire
and terminal #8 black wire of the material
PAKSTAT?
•
Yes, check for loose or broken wires
between terminal block and terminal #4 of
the material PAKSTAT.
•
No, go to Step 7a.
Table 8-4 Burner Electrical Troubleshooting – 4LE2 Engine (continued)
Summary of Contents for Crafco 46200EB