EZ 1000 Series II Melter Part Manual
Chapter 8 Troubleshooting
©2019 by Crafco, Inc. All Rights Reserved………………...………………………………..……………...Troubleshooting 8-30
Step
Possible Cause
If . . .
8
Is there 12Vdc between the Hose Selector
switch pink wire labeled “PNK-4 (bottom left
terminal) and a near” ground source black
wire?
•
Yes, check for loose or broken wires
between switch and upper terminal block.
•
No, go to Step 8a.
8a
Is there 12Vdc between the Hose Selector
switch pink wire Labeled “PNK-3” center left
terminal and a nearby ground source.
•
Yes, replace Hose Selector switch.
•
No, go to Step 9.
9
Is there 12Vdc between pink wire labeled
“PNK-3 on the upper terminal block and a
nearby ground source black wire?
•
Yes, check for loose or broken wire
between terminal block and hose selector
switch.
•
No go to Step 9a.
9a
Is there 12Vdc between pink wire labeled
“PNK-2” on upper terminal block and nearby
ground source black wire?
•
Yes, replace terminal block.
•
Steps 4a
through 10a.
Table 8-28 Electrical Troubleshooting (continued)
Fig. 8-10 Junction Box Voltage Testing
Test #2 between
black and green
Test #1 between
black and white
wires
Test #3 between
white and green
wires