background image

888-SV-22DL-00 rev C

1

1

a

b

c

e

22.3"

566 mm

38"

965 mm

28"

711 mm

18"

457 mm

50.8"

1290 mm

24"

610 mm

Dimensions

CAUTION: 

The lift brake locks 

vertical lift of riser during 

normal use but it DOES NOT increase 
load capacity.  DO NOT load riser with 
equipment totalling more than the 
maximum weight capacity specifi ed by 
Ergotron.  Ensure optimum lift function 
by testing and if necessary, re-adjusting 
tension whenever the weight mounted 
to the riser changes (i.e., equipment is 
removed or added). See "Set Riser Lift 
Tension" adjustment instructions  in 
step 9 on page 5.

Cart Specifi cations 

- For Power System Specifi cations see page 12.

Vertical Adjustment Range: 

  20" (508 mm)

LCD Tilt:  ± 25° Viewing Angle

Based on a 17" VESA Compliant LCD

STAND

SIT 

18"

457 mm

21"

533 mm

v

136 mm

v

533 mm

70.5"

1791 mm

44"

1118 mm

21" *

533 mm

*

 21" (508mm) is the recommended distance between 

top of keyboard tray and top of monitor screen. 

Riser at Full Height

Riser in Lowest Position

Range of motion

For more information on this 

or other Ergotron products, 

visit our website: 

www.ergotron.com

Weight capacities

Keyboard Tray Tilt:  -12° 

Please read all parts of this guide. When set-up is complete, do not discard 

this guide. The guide should be fi led in a secure place for future reference.

d

*

 If display is greater than 18 lbs 

contact customer care for fi xed pivot.

Display*

6-18 lbs

2.72-8.26 kg

Drawer

4 lbs

1.8 kg

Worksurface

2.5 lbs

1.1 kg

CPU Holder

25 lbs

11 kg

Keyboard Tray

2.5 lbs

1.1 kg

Mouse Holder

.5 lb

.23 kg

Scanner Holder

.5 lb

.23 kg

Basket

5 lbs

2.3 kg

Features 

SV22-92023

1  

Riser

LCD Pivot

3

  5" Lift

4  

Worksurface

5  

Electronic Autolock Drawer 

6  

Tilting Keyboard Tray and Wrist Rest

7  

Right/Left Mouse Tray and Holder

8  

Cable Management 

9  

Riser Lift Brake

10  

Locking Front Casters

11  

Scanner Holder Bracket

12  

Ergonomic Rear Handle

13  

Storage Basket

14  

CPU Holder

15  

Power System - 120VAC/60 HZ

a

 55 Ah Battery

b

 4 AC Outlets (300 Watts total)

c

 Remote User Interface (RUI)

d

 StyleLink Software CD & Cable

e

 Coiled Power Cord

EN

StyleView powered 
carts provide 
electrical AC power for 
mobile point of care 
computing equipment 
in a healthcare 
environment.

Summary of Contents for StyleView SV22-92023

Page 1: ...or more information on this or other Ergotron products visit our website www ergotron com Weight capacities Keyboard Tray Tilt 12 Please read all parts of this guide When set up is complete do not dis...

Page 2: ...To prevent the riser from moving during set up lock riser by pushing the lift brake down a b b WARNING The riser can move up on its own very quickly when a counter balancing force is removed Therefor...

Page 3: ...er won t open when Personal Code is entered Test system by entering Master Code If drawer doesn t unlock replace batteries as instructed 5a above Low Voltage Alert Master Code Master Code New Code Mas...

Page 4: ...lift brake to keep riser down and equipment secure while cart is in motion 4 Unlock both front casters 5 Push cart from rear with elbows bent at about 90 to maximize control and minimize muscle strain...

Page 5: ...ords down the channel to the outlets under the front cover Connect the RUI cables and plug in the power cords CAUTION Route cables on Cable Channel right side of Cart only Do not store power brick ins...

Page 6: ...t stay in the desired position the titlt tension should be adjusted b a b d e Battery Charging Cycle a Plug power cord into appropriate wall outlet and verify that the green 100 light is flashing to i...

Page 7: ...ge empties to 0 or when the power cord is plugged in for recharging NOTE If the alarm light is off the beeping has been disabled and the alarm is mute For details on enabling and disabling alarm conta...

Page 8: ...efore storing c Once battery has been charged to 100 turn power system off by holding down the AC Outlet Power on the RUI for 1 3 seconds Power light will shut off d Leave power cord plugged into appr...

Page 9: ...tlet box e Remove battery cover f Unplug cord reel for better access g Remove protective boot from Black lead Be careful not to contact tools between terminals on battery and metal chassis Use wrench...

Page 10: ...so in the installation instructions Moving Cart components too high or too low on the Riser may create an unstable condition leading to equipment damage or even personal injury Contact Ergotron Custom...

Page 11: ...justment information 6 Stay in charge Powered carts should be plugged into outlet as often as possible to keep battery charged and computer running 2 1 3 5 4 6 Moving stow before you go 1 Look where y...

Page 12: ...ture is 20 C 4 F and the maximum storage temperature is 50 C 122 F The recommended humidity range for storage is 0 95 rH The cart and power system are certified to UL 60601 and CAN CSA C22 2 601 1 M90...

Page 13: ...operly connected to the Cart Outlet box If the RUI is not illuminated try trouble shooting problem 1 before continuing on to step b b Disconnect all equipment from the cart outlets Use an outlet teste...

Page 14: ...888 SV 22DL 00 rev C 14...