888-SV-22DL-00 rev C
12
8
Cart Safety Guidelines
The autolock drawer has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Changes or modifi cations not expressly approved by Ergotron, Inc.
could void the user’s authority to operate the equipment.
Please contact Ergotron for complete EMC compatibility information.
FCC Compliance Statement
- Cart and Autolock Drawer
SV22-92023
Power System Specifi cations
- 120VAC/60 Hz power system
Input: 120VAC/60 Hz, 5.1A
Output: 120VAC/60 Hz, 400VA 300W
The StyleView AC Power System (SPS) allows your power supply to travel with the cart. The Power System is
integrated in the base of the cart and comes standard with a battery, true sine wave inverter, ATS, RUI, charger,
isolation transformer, outlet box and power cord.
• True Sine Wave Inverter (TSW): designed to ensure satisfactory operation of Power Factor Corrected devices like
Flat Panel Monitors.
• Automatic Transfer Switch (ATS): allows connected computer equipment to switch to “house” power when
charging the battery.
• Remote User Interface (RUI): Located near worksurface, allows power system output to be turned on or turned
off , allows monitoring of battery charge left, and provides low battery charge audible alarm.
• 55Ah Sealed Lead Acid, Absorbed Glass Mat, Valve Regulated & Recombinant Gas Type, 12VDC battery.
• The recommended cart storage temperature is 15°C (59°F). At this temperature, the 55Ah battery’s age-related
capacity loss is minimized. The minimum storage temperature is -20°C (-4°F) and the
maximum storage temperature is 50°C (122°F). The recommended humidity range for
storage is 0-95% rH.
• The cart and power system are certifi ed to UL 60601 and CAN/CSA-C22.2 601.1-M90
For more information on this or other Ergotron products,
visit our website:
www.ergotron.com
Color
Symbol
Signal
Word
Level of Hazard
Red
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
Orange
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Yellow
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
None
CAUTION
Used without the safety alert symbol indicates a poten-
tially hazardous situation which, if not avoided, may
result in property damage.
Red,
Orange
or
Yellow
Electrical
Indicates an impending electrical hazard which, if not
avoided, may result in personal injury, fi re and/or death.
Hazard Symbols Review
The Meaning of Symbols appearing in this Guide, on the Cart or on the Power System
These symbols alert you to a safety condition that demands your attention. You should be able to
recognize and understand the significance of the following Safety Hazards if you encounter them on
the Cart or within Cart documentation such as this Set-up Guide.
Product Marks
BATTERY
LEAD
-20 °C
- 4 °F
50 °C
122 °F
Relative
Humidity
Range
0-95% rH
$!.'%2
ELECTRICAL CORDS CAN BE HAZARDOUS
-ISUSE#AN2ESULTIN&)2%OR$%!4(BY%,%#42)#!,3(/#+
0LEASE2EADAND&OLLOW0RODUCT-ANUAL)NSTRUCTIONS
4()3)3!0/,!2):%$#/2$(/30)4!,'2!$%/.,9
./4%'ROUNDING2ELIABILITY#AN/NLY"E!CHIEVED7HEN
THE%QUIPMENT)S#ONNECTED4O!N%QUIVALENT2ECEPTACLE-ARKED
h(/30)4!,/.,9v/Rh(/30)4!,'2!$%v
s)NSPECT#ORD4HOROUGHLY"EFORE%ACH5SE$/./453%)&$!-!'%$
s$O.OT0LUG-ORE4HAN30%#)&)%$.5-"%2/&7!443)NTO0OWER3YSTEM
s$O.OT2UN#ORD4HROUGH$OORWAYS(OLESIN#EILINGS7ALLSOR&LOORS
s&5,,9).3%240LUG)NTO/UTLET
s$O.OT2EMOVE"ENDOR-ODIFY!NY-ETAL0RONGSOR0INSOF#ORD
s$O.OT5SE%XCESSIVE&ORCETO-AKE#ONNECTIONS
s+EEP!WAY&ROM7ATER$/./453%7(%.7%4
s+EEP#HILDREN!WAY&ROM#ORD
s$O.OT0LUG#ORDINTO!N%XTENSION#ORD
s!6/)$/6%2(%!4).'5NCOIL#ORDAND$O.OT#OVER)T7ITH!NY-ATERIAL
s$O.OT$RIVE$RAGOR0LACE/BJECTS/VER#ORD$O.OT7ALK/N#ORD
s'2!300,5'TO2%-/6%&2/-/UTLET$O.OT5NPLUG"Y0ULLING/N#ORD
Summary of Contents for StyleView SV22-92023
Page 14: ...888 SV 22DL 00 rev C 14...