30(42)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved
Kontr/Checked
Tillhör/Referens-File/Reference
1999-07-15
F
1545-ASB 150 02 Uen
FAULT TRACING DESCRIPTION
Faktaansvarig - Subject responsible
’No connection
Y
N
Cable correct?
Check PC cabling:
from COM1 via
connection board
END
Replace desk charger/
programmer
Correct cabling
N
Y
CSM Problem
message
PC screen?
with DCT1800’ on
to IC-CU
N
Y
Cabling correct ?
- COM1 port of PC
- IC- CU board
- Serial PC cable
connection
N
Y
’No
desk charger
message?
with portable in
Check desk charger/
programmer cable
Replace cable
connection
Y
N
’No
desk charger
message?
with portable in
COM2 port of PC
’Init’ on portable
N
Y
displayed ?
displayed when
N
Y
’Init’ is
another
portable?
programming
Adapter correct
N
Replace adapter or
connect properly
Y
and properly
connected?
Portable
N
Try to correct contacts or
replace desk charger
Y
makes proper
charger
contact with
pins?
Portable
defect
Portable
defect
Desk Charger/
Programmer
defect
From
page 25