5(23)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved
Kontr/Checked
Tillhör/Referens-File/Reference
1999-07-15
E
1541 - ASB 150 02 Uen
Faktaansvarig - Subject responsible
1.4
Upgrading Program
1.4.1
Installation
Before starting refer to the hardware requirements mentioned before. The binary software files and the
upgrading program chkdiff.exe are available on the support server at SEA.
Note: Chkdiff.exe requires a 32-bit operating system such as MS-Win95 and MS-WinNT4.0.
All registered users can download these files. Download the ASB15002 SW file for the required release
from the server. Copy the upgrade program and the ASB 150 02 software files into a dedicated directory.
These files are compressed and after extraction the following binary ASB15002 files are available e.g. as
listed below:
Check in the read me file the version of the available program and compare it with the program version
installed in the PBX to be updated. All three binary files are needed to install a complete SW upgrade.
1.5
Creating the Output File
The first step is to create an output file that shall be loaded into the exchange. Refer to the read me file
giving details of the version of the software to be upgraded to and compare it with the program version
installed in the PBX to be updated. It is important to know your market version to perform the upgrade for
details refer to the ORDERING INFORMATION (131 62-1x/ASB150 02) or the index of the software e.g.
LZY 203 2230/x. The x states the market version needed to create the upload file.
Execute the 32 bit console application program chkdiff.exe in a DOS prompt. The program chkdiff.exe
generates the file which is used for uploading the new SW-version. This application verifies which parts
of the SW has been changed, determines the differences between the two SW-versions and creates an
output file (*.txt). The file is a specially coded (containing line number, checksum, ...) but must not be
opened by any tool (e.g. editor) as in this case the data may be corrupted.
•
readme.txt
This file contains information on the software version
•
101RA21.me
These files are necessary for the upgrading program
•
A11R1AA.bin
•
A21R1A.bin and
These files are extracted from the current ASB15002 SW
•
A31R1A.bin
.
. . . .
zip files: They are available on the FTP site.