EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
116 (200)
7.15
Configure SHDSL Line Profiles
Note:
This section ONLY applies to SHDSL Profiles.
Configure the EDA2530 SHDSL Line Profiles via the LCT.
a.
From the LCT main screen select the path
Configuration > SHDSL
Profiles and Setup
. Click
Conf Profiles
button. The “SHDSL Conf
Profiles” screen will be displayed:-
Note:
If there is an SHDSL card already configured in the EDA2530 then
click the
Read Network
button to view and check the SHDSL Line Profiles.
If the profiles are correct this sub-section is not required. If the profiles are
not correct then perform the rest of this sub-section.
b. Select
File
>
Open
, then navigate to the “SHDSL Line Profiles.lcp” template
file. Then select
Open
to load this profiles file.
c.
In the “
Ne Name”
column the template will load the default OOB IP
address of 150.150.150.4, the Node being commissioned is likely to have a
different one allocated to it. The Out Of Band IP Address is determined by
the DLE ID, refer to Section 5.5. Change the address (if necessary) in this
column for all entries, as follows:-