Profile Name
Wire Interface
Min Line Rate bps
Max Line Rate bps
1 2
Wire 192K 5696K
Ultra-Short 2
Wire
192K
5696K
Extra-Short 2
Wire
768K
3072K
Short 2
Wire
768K
2752K
Medium 2
Wire
512K
2048K
Long 2
Wire
256K
1024K
Profile Name
Downst
CurrCond
Downst
WorstCase
Upst
CurrCond
Upst
WorstCase
Used SNR
Target
Margins
1 5 5 5 5
CurrCondDown
Ultra-Short
5 5 5 5
CurrCondDown
Extra-Short
5 5 5 5
CurrCondDown
Short 5 5 5 5
CurrCondDown
Medium
5 5 5 5
CurrCondDown
Long 5 5 5 5
CurrCondDown
The above tables show a typical example of SHDSL Line Profiles. Actual required
SHDSL Line profiles should be supplied by the Customer.
7.16
Configure SHDSL Stack Profiles
Note:
This section ONLY applies to SHDSL Profiles.
Configure the EDA2530 SHDSL Stack Profiles via the LCT.
a.
From the LCT main screen select the path
Configuration > SHDSL
Profiles and Setup
. Click
Stack Profiles
button. The “SHDSL Stack
Profiles” screen will be displayed:-
Note:
If there is an SHDSL card already configured in the EDA2530 then
click the
Read Network
button to view and check the SHDSL Stack
Profiles. If the profiles are correct this sub-section is not required. If the
profiles are not correct then perform the rest of this sub-section.
b. Select
File
>
Open
, then navigate to the “SHDSL Stack Profiles.psp”
template file. Then select
Open
to load this profiles file.