EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
119 (200)
c.
In the “
Ne Name”
column the template will load the default OOB IP
address of 150.150.150.4, the Node being commissioned is likely to have a
different one allocated to it. The Out Of Band IP Address is determined by
the DLE ID, refer to Section 5.5. Change the address (if necessary) in this
column for all entries, as follows:-
Change the 1
st
entry in this column to the correct IP address, select the 1
st
entry, then left-click the 1
st
entry & drag down to the bottom of the column
to highlight all entries. Right click & select “
Replicate cell
”, all entries in the
“
Ne Name”
column will now be set to the required OOB IP Address.
d.
In the “
Command
” column, in the 1
st
entry double click the empty field and
select the “
create
” option from the drop-down list. Select the 1
st
entry, left
click & drag down to the bottom of the column to highlight all entries. Right
click & select “
Replicate cell
”, all entries in the “
Command”
column will
now be set to “
create
”.
e. Select
the
Apply Selection
button. All entries should turn green.
f. Select
“
Read Network
”, now wait for the fields in the table to be filled in,
refer to the following example screen.
When the “Stored Entries” are shown black all entries have been read.