EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
126 (200)
7.17.6
Step 5: Configure RTP Profiles
a.
From the LCT main screen select the path;-
Configuration
>
POTS/ISDN Profiles
b. Select
“
File
” then “
Open
”, and navigate to the relevant folder to select the
“
Generic POTS RTP Profiles”
file.
For all sites this will be “
Generic POTS RTP Profiles.rtp
”.
Select
“
Open
” then the RTP Profiles table will be filled in and the following
screen will be displayed:-
NOTE:
Each potential POTS cards must have its own RTP profile configured. One
is assigned to each card being used. (e.g. RTP151 = Slot3, RTP152 = Slot
5… etc)
c.
In the “
Ne Name”
column the template will load the default OOB IP
address of 150.150.150.4, the Node being commissioned is likely to have a
different one allocated to it. The Out Of Band IP Address is determined by
the DLE ID, refer to Section 5.5. Change the address (if necessary) in this
column for all entries, as follows:-
Blank
Blank
Blank