EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
127 (200)
Change the 1
st
entry in this column to the correct IP address, select the 1
st
entry, then left-click the 1
st
entry & drag down to the bottom of the column
to highlight all entries. Right click & select “
Replicate cell
”, all entries in the
“
Ne Name”
column will now be set to the required OOB IP Address.
d.
Scroll right to the “Default GW IP Addr” column
e. The
“
Default GW IP Addr
” column must now be filled in with the Default
GW addresses for all ten POTS cards slots 3 to 21. (Even if only one POTS
card is physically installed.)
Explanation:
The Def GW IP Addresses are determined from the POTS
cards IP Addresses, if the POTS card IP Addr = a . b . c . d
So the Def GW IP Addr becomes =
a . b . c+1 . 254
In this example the following POTS card Def GW IP Addresses have been
used:-
POTS
Slot No.
Profile
No.
POTS Card IP
Addr
POTS Card
Def GW Addr
3 2
10.67.130.102
10.67.131.254
5 3
10.67.132.102
10.67.133.254
7 4
10.67.134.102
10.67.135.254
9 5
10.67.136.102
10.67.137.254
11 6
10.67.138.102
10.67.139.254
13 7
10.67.140.102
10.67.141.254
15 8
10.67.142.102
10.67.143.254
17 9
10.67.144.102
10.67.145.254
19 10
10.67.146.102
10.67.147.254
21 11
10.67.148.102
10.67.149.254
Refer to the following figure.