h.
Click on the
Apply
button to modify the Connection Module configuration.
i.
When the ADSL card is fitted
WITHOUT
an associated POTS/VoIP card,
check that all of the POTS Pass Back boxes are
ticked
for all ports 1 to 64.
If any port(s) is not ticked click in the port boxes to select and then click the
Apply
button. Click on the
Refresh
button and check that all of the POTS
Pass Back boxes are ticked for all ports 1 to 64.
j.
When the ADSL card is fitted
WITH
an associated POTS/VoIP card, check
that all of the POTS Pass Back boxes are
unticked
for all ports 1 to 64.
If any port(s) is ticked click in the port boxes to deselect and then click the
Apply
button. Click on the
Refresh
button and check that all of the POTS
Pass Back boxes are unticked for all ports 1 to 64.
k.
When the SHDSL card is fitted check that all of the POTS Pass Back boxes
are
unticked
for all ports 1 to 64. As shown in the “Configure selected
Connection Module” window above.
l.
Repeat the steps c to k for all other iTAM Connection Units
(02HAT00282AAQ) and (02HAT00136AAR) installed.