EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
21 (200)
2.4.4.2
64 x POTS/VoIP Unit (02HAT00198AAM)
EDA 2530 subrack:-
The 64 x POTS/VoIP Unit should be fitted in the
Odd Slots
Only,
from slots 3 to slot 21 with up to a maximum of ten cards, providing a
maximum of 640 lines. Each 64 x POTS/VoIP card requires its relevant Connection
Unit to be fitted above the 64 x POTS/VoIP card.
Note:
When the combination of 64 x ADSL2+ and 64 x POTS/VoIP Units are
used, the Connection Unit required is the 64 x COMBI I/F + IN/Out POTS + TAM
ETSI Connection Unit (02HAT00282AAQ).
Figure 2.7 – 64 x POTS/VoIP Unit
The card front is equipped with 3 LED’s whose functions are as follows.
T
(
yellow)
On
unit normal activity
Off
unit has a protecting role
Blinking
configuration is being changed.
PWR
(green)
On
unit is powered up
ALARM (red)
Off
normal activity
On internal
alarm.
Blinking
external
alarm
T
PWR
RS
2
3
2
0
2
HA
T
0
0
198 AA
M
PO
TS
/V
o
IP
x
64
T
PWR
RS
2
3
2
0
2
HA
T
0
0
198 AA
M
PO
TS
/V
o
IP
x
64