EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
42 (200)
4.3.3
Cabling
Check that the positions of service or signal cable terminations on electrical and
optical distribution frames, or on other equipment, comply with the Site
Implementation Plan.
Check that the 64 pair cables (Lines and POTS) are tied on the provided cable
supports. Check that Line cables are linked to the Connection Unit through the
supports supplied with the equipment.