EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
54 (200)
5.4
Logon to The EDA 2530 Via LCT
a.
Connect the PC to the Common Part card using the Ethernet cable (Ref:
3.3).
b. Select
Start
>
All Programs
>
AXH-EDA Local Terminal xx.yy.zz
>
PortSrv
c. Select
Start
>
All Programs
>
AXH-EDA Local Terminal xx.yy.zz
>
AXH-
EDA Local Terminal
Or select the “
AXH-EDA Local Terminal
” shortcut from the desktop.
A window with ‘Starting Local Terminal. Please wait…’ will be displayed.
d.
After around 15 seconds the ‘Equipment Logon’ window will be displayed.
e.
Enter in the
Equipment Address
field, the IP Ethernet Address for the CP
unit, ie 150.150.150.4.
Then click on
Logon
.
f.
If everything has been carried out correctly, then after around 2.5 minutes
the equipment view window will be displayed, showing the created unit(s).