EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
72 (200)
7.2
Configure CP Ethernet Interfaces
7.2.1
Configure CP Port 1
Configure CP Port 1 GigE interface to be the In Band Management interface.
a.
Right click on the CP Card and select
Ethernet Lines
from the sub menu.
b.
Select the “
Port 1
” button, then click on “
Configure
”, the following window
will be displayed:-
c.
From the “Configuration” folder tick the
Local In-Band Mng
tick box. Then
click on the “
Apply
” button that is immediately to the left of the tick box.
d.
Select the “
MAU
” folder, the following window will be displayed:-