EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
85 (200)
d.
Click on the “
Accept selected entries
” button, the display will revert back
to the “Static VLAN Members” table.
For the SHDSL card(s), new “intLag” interfaces will now be created in the
“DATA_INBAND” S-VLAN, as shown in the following typical screen.
e.
In the “
Command
” column, against the new “intlag//1/..” entries just
created, double click on the empty field and select the “
addPort
” option
from the drop-down list. All new entries in the “
Command”
column will now
be set to “
addPort
”.
f. Select
“
Apply All
” from the bottom LHS of the screen. The rows will turn
Green and under the “Result” column the field should display “
OK
”.
g. Select
“
Read Network
” near the top of the screen, this will confirm the
configuration, if there are any incorrect entries they will be highlighted at
this point.
7.7.3
Create S-VLANs for POTS Cards (If required)
An “intLag” interface must be created for each POTS card against the appropriate
VOIP_GWx
name for the relevant slot. Proceed as follows:-
a.
If the slot 3 POTS card is to be configured, double left-click on the
“
ethG//1/1/1
” entry in “User Port Interface Name” column against
“
VOIP_GW1
”. Refer to the table below for POTS slot vs. S-VLAN names.