EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
97 (200)
c.
In the “Lower Interf Name” field select “
BVI
” (Bridged Virtual Interface) from
the drop-down list.
d.
In the “
C-VLAN ID
” field enter the appropriate value for the type of EDA
2530, refer to the table below.
C-VID ID
EDA 2530
3200 “Parent”
200 “Child#1”
1200 “Child#2”
2200 “Child#3”
e.
In the “
S-VLAN ID”
field enter the VLAN number to be used for In-Band
management. Check with the CWA “DLE Planning” document what the S-
VLAN ID value should be set to for the node being commissioned. This
value will be either 21 or 22.
f.
In the “Subinterface Number” field select the
<auto increment>
option.
g.
Now save the details by clicking on “
Create
”.
h.
Close all windows to return to the main LCT screen.