28
Figure 26 - Mounting Bracket Installation
6.
Connect front mount accessory cable connector P2 to speaker cable
connector.
7.
Connect power cable to power connector on rear of radio unit and
secure with the two captive screws to the radio unit.
8.
Connect microphone connector to connector on front panel and
secure with captive screw.
NOTE
Do not torque microphone connector screw greater than 2 in-lb.
Alternatively, finger tight plus 1/4 turn is acceptable.
9.
If there are no other accessory connections, tie back plug P3 to main
cable.
10. Recheck all connections before inserting fuse into transmit fuse
assembly.
Top Mount
Bottom Mount
9
INSTALLATION IN VEHICLES POWERED
BY LIQUEFIED (LP) GAS
Radio installation in vehicles powered by liquefied petroleum gas
with the LP gas container in the trunk or other sealed-off space
within the interior of the vehicle must conform to the National Fire
Protection Association Standard NFPA 58 which requires that:
•
Space containing radio equipment shall be isolated by a seal from
the space containing the LP gas container and its fittings.
•
Outside filling connections shall be used for the LP gas container.
•
The LP gas container space shall be vented to the outside of the
vehicle.
INSTALLATION
RUNNING CABLES
To assure the feasibility of the planned cable routings, it is suggested
that the cables be run before mounting the radio. The Orion mobile
radio may be installed as a Front Mount, Remote Mount or Cassette
Mount. The type of mount, the application and the options to be
installed should be considered when planning the cable runs. Figures 5-
12 provide Interconnection Diagrams for typical installations. Figures
5-12 should be referenced throughout this manual and throughout the
installation.
Be sure to leave some slack in each cable going to the radio so that the
radio may be pulled out for servicing with the power applied and
antenna attached. Coil any surplus cables and secure them out of the
way. Try to route the cables away from locations where they will be
exposed to heat (exhaust pipes, mufflers, tailpipes, etc.), battery acid,
sharp edges or mechanical damage or where they will be a nuisance to
automobile mechanics, the driver or passengers. Keep wiring away from
electronic computer modules, other electronic modules and ignition
circuits to help prevent interference to these components and radio
equipment.
In addition, try to utilize existing holes in the firewall, trunk wall and
the channels above or beneath doors. Channels through door and
window columns that are convenient for running cables may also be
used, unless rigid or flexible conduit is to be installed for cable runs.
Summary of Contents for LBI-38901B
Page 1: ...Printed in U S A LBI 38901B Mobile Communications ORION MOBILE RADIO Installation Manual ...
Page 5: ...32 Figure 29 Cassette Assembly Schematic Diagram 5 Figure 3 Cables ...
Page 32: ...32 Figure 29 Cassette Assembly Schematic Diagram 5 Figure 3 Cables ...
Page 36: ...Printed in U S A LBI 38901B Mobile Communications ORION MOBILE RADIO Installation Manual ...