LBI-39224
3-143
This option should only be disabled (unselected) in special
circumstances in which routing all calls would cause excessive NIM
traffic. In general, StarGate/NIM networks which require large
amounts of console dispatch operations will require enabling of this
option.
Remote CEC Interface
This function allows all call traffic being monitored by a console or
logging recorder on a remote CEC system to be routed by the NIM link.
This option must be enabled at both NIMs in the link. The default is
disabled (check box unselected) and it should only be enabled
(selected) for remote CEC (console only node) links.
Serial Control Link Baud Rate
This drop-down list box allows setting of the NIM control data link
baud rate. This link is the control data connection between Network
Interface Modules (NIM) coupling two CEC/IMC or StarGate Digital
Audio Switches together. The NIM on each end of the link must be
manually set to equal baud rates via this field. Select the required value
from the available baud rates of 9600, 19.2k, and 38.4k.
Save and Send StarGate Configurations
When the StarGate configurations for all the NIMs have been
completed, they must be saved and then sent across the multisite
network.
Save
Choose the
Save
button to perform an immediate save of the currently
selected NIM configuration. Other NIMs displayed in the list box
located at the top of the dialog box are not saved. The configuration is
saved on the CEC/IMC Manager's hard disk drive. Any previous
StarGate configuration for the NIM, if present, is erased and replaced
with the current configuration. If the CEC/IMC Manager is running
remotely or as a part of the EDACS Network Manager, this
configuration is saved on the CEC/IMC Manager local to the
CEC/IMC; it is not saved at the remote location.
Send
Choose the
Send
button to send the NIM configuration across the IMC
network. This procedure must be performed before the NIM will
operate with the new configuration.
Summary of Contents for LBI-39224
Page 1: ...LBI 39224 ericssonz Operations Guide EDACS CEC IMC MANAGER Version 5 0 for Windows NT...
Page 2: ......
Page 6: ...LBI 39224 vi This page intentionally blank...
Page 16: ...LBI 39224 xvi This page intentionally blank...
Page 22: ...LBI 39224 1 6 This page intentionally blank...
Page 30: ...LBI 39224 2 8 This page intentionally blank...
Page 238: ...LBI 39224 3 208 This page intentionally blank...
Page 268: ...LBI 39224 4 30 This page intentionally blank...
Page 304: ...LBI 39224 D 2 This page intentionally blank...
Page 312: ...LBI 39224 E 8 This page intentionally blank...
Page 324: ...LBI 39224 G 12 This page intentionally blank...