Conditional Access
D.4.3
Set Up an EMM Generator
D.4.3.1
Streaming EMMs to Multiple Output Transport Stream
MX8400 Release 5
allows a single EMMG connection providing a single EMM
stream to be distributed to all the required output transport streams.
Note:
Refer to the nCC Setup information for further details.
•
The EMM is currently defined in the Service Plan in each output Transport
Stream. This continues to be the case to allow for backward compatibility.
•
The MX8400 identifies EMMs which are unique to one output transport stream.
•
The MX8400 identifies EMMs which are common to multiple output transport
streams.
•
A single EMMG connection is made for those EMMs that are shared across
multiple output streams.
•
Where EMMs are shared across multiple output streams, each stream is
allocated the same EMM bit rate by nCC within the service plan.
•
Where EMMs are shared across multiple output streams, MX8400 output
transport stream isolation applies.
Note:
Where EMMs are shared across multiple output transport streams, any
corruption of the EMM input stream affects all output transport streams.
D.4.3.2
EMM/PD Capabilities
•
8 EMMG/PDG TCP/IP connections( Simulcrypt channels) per a MX8400 chassis
(8 shared between EMMG and PDG connections)
•
16 EMM streams per an EMMG/PDG TCP connection.
•
2 Mbps combined of EMM/PD per multiplexer engine.
•
Maximum of 8 Mbps of EMM/PD as measured by the MX8400 in total.
•
TCP control and de TCP control and UDP delivery
•
Single shared EMM TCP port for all connections
•
Single shared EMM UDP port for all connections
D.4.3.3
EMM DVB Simulcrypt Injector Dialog Box: Device Tab
This section describes how to set up an EMMG in nCompass Control.
2/1553-FGC 101 1014 Uen B
D-9
Summary of Contents for MX8400
Page 1: ...MX8400 Multiplexer Software Version 5 2 0 and later REFERENCE GUIDE 2 1553 FGC 101 1014 Uen B...
Page 26: ...Installing and Powering Up 2 1553 FGC 101 1014 Uen B 2 4 BLANK...
Page 94: ...Operating the Multiplexer using nCompass Control 2 1553 FGC 101 1014 Uen B 4 18 BLANK...
Page 96: ...Preventive Maintenance and Fault finding 2 1553 FGC 101 1014 Uen B 5 2 BLANK...
Page 146: ...Technical Specification 2 1553 FGC 101 1014 Uen B B 20 BLANK...
Page 148: ...Static Parameters 2 1553 FGC 101 1014 Uen B C 2 BLANK...
Page 186: ...Redundancy Modes 2 1553 FGC 101 1014 Uen B E 2 BLANK...
Page 192: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 2 BLANK...
Page 196: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 6 Figure F 3 Editing Stack Download Ports...
Page 198: ...ProMPEG FEC Support for IP Streaming 2 1553 FGC 101 1014 Uen B G 2 BLANK...
Page 204: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 2 BLANK...
Page 212: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 10 BLANK...
Page 214: ...PSIG Support 2 1553 FGC 101 1014 Uen B I 2 BLANK...
Page 220: ...BISS Support 2 1553 FGC 101 1014 Uen B J 2 BLANK...