Technical Specification
B.6
AC Supply
This equipment is fitted with dual wide-ranging power supply suitable for supply
voltages of 100-240 V AC -10% +6% at 50/60 Hz nominal.
Table B.14 Supply Specification
Item Specification
Power distribution
system
Type TN ONLY (EN 60950-1 Annex V): Power distribution
system which is directly earthed, the parts of the equipment
required to be earth being connected by Protective Earthing
Conductors.
This equipment must NOT be used with
single-phase three-wire
and PE, TT or IT Type Power
distribution systems.
Connection to
supply
Pluggable Equipment Type A (EN 60950-1 para 1.2.5):
Equipment which is intended for connection to the building
power supply wiring via a non-industrial plug and socket-outlet
or a non-industrial appliance Coupler or both. Correct mains
polarity must always be observed. Do not use reversible plugs
with this equipment
Class of equipment Class
I
Equipment (EN 60950-1 para 1.2.4): electric shock
protection by basic insulation and protective earth
Rated voltage
[Operating voltage]
100-240 V AC (single phase)
Rated frequency
[Operating freq]
50/60 Hz [48-63 Hz]
Voltage selection
Wide-ranging
Rated current
4.0 - 2.0 A, 100 – 240 V AC
Input connector
AC power input filter with CEE 22/IEC320 plug
Fuse
Fuse in live conductor in power input filter at rear of unit.
Fuse type
Bussmann S505
Littelfuse 215
5x20 mm time delay (T) 1500 A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
Fuse current rating 5 A 250 V T HBC
Power
consumption
80 W (NO options fitted)
2/1553-FGC 101 1014 Uen B
B-12
Summary of Contents for MX8400
Page 1: ...MX8400 Multiplexer Software Version 5 2 0 and later REFERENCE GUIDE 2 1553 FGC 101 1014 Uen B...
Page 26: ...Installing and Powering Up 2 1553 FGC 101 1014 Uen B 2 4 BLANK...
Page 94: ...Operating the Multiplexer using nCompass Control 2 1553 FGC 101 1014 Uen B 4 18 BLANK...
Page 96: ...Preventive Maintenance and Fault finding 2 1553 FGC 101 1014 Uen B 5 2 BLANK...
Page 146: ...Technical Specification 2 1553 FGC 101 1014 Uen B B 20 BLANK...
Page 148: ...Static Parameters 2 1553 FGC 101 1014 Uen B C 2 BLANK...
Page 186: ...Redundancy Modes 2 1553 FGC 101 1014 Uen B E 2 BLANK...
Page 192: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 2 BLANK...
Page 196: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 6 Figure F 3 Editing Stack Download Ports...
Page 198: ...ProMPEG FEC Support for IP Streaming 2 1553 FGC 101 1014 Uen B G 2 BLANK...
Page 204: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 2 BLANK...
Page 212: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 10 BLANK...
Page 214: ...PSIG Support 2 1553 FGC 101 1014 Uen B I 2 BLANK...
Page 220: ...BISS Support 2 1553 FGC 101 1014 Uen B J 2 BLANK...