Conditional Access
D.4.2.4
DVB Simulcrypt ECM Generator Dialog Box: ECM Generator Tab
Table D.2 Set Up an ECM Generator (continued)
Step Action
Result
Comments
Enter the
IP address
of the ECMG
Enter the
CA System
ID
Enter the required
CA
Subsystem ID
The CA vendor
supplies this
information
Each vendor can allocate a CA Subsystem ID
in the range 00-FF. It is a two byte
hexadecimal number. This is to differentiate
between systems supplied by the same
vendor.
If the CASID is not on the drop-down list in the
GUI, type it in.
5
Enter the
max no. of
ECM
stream
s
that
this ECMG will
require.
The maximum number of ECM streams to be
used may be unknown at this time. This
should be set to a reasonably high number
(e.g. 256) so more ECM streams can be
added at a later date. If the maximum number
of ECM streams is set too low, nCC server will
report that it is unable to route the CA.
D.4.2.5
DVB Simulcrypt ECM Generator Dialog Box: CA Types Tab
Table D.2 Set Up an ECM Generator (continued)
Step Action
Result
Comments
6
Click the
CA Types
tab and select the
required
CA Type
The CA Types setting
enables nCompass to
map services to
specific ECM
generator
In most cases the CA type
Any
is used. If
more than one type of CA scrambling is used,
the list on the right should show the CA types
defined earlier in
Section D.4.1
7 Click
OK
The configured ECM
Generator is added to
the physical map
2/1553-FGC 101 1014 Uen B
D-8
Summary of Contents for MX8400
Page 1: ...MX8400 Multiplexer Software Version 5 2 0 and later REFERENCE GUIDE 2 1553 FGC 101 1014 Uen B...
Page 26: ...Installing and Powering Up 2 1553 FGC 101 1014 Uen B 2 4 BLANK...
Page 94: ...Operating the Multiplexer using nCompass Control 2 1553 FGC 101 1014 Uen B 4 18 BLANK...
Page 96: ...Preventive Maintenance and Fault finding 2 1553 FGC 101 1014 Uen B 5 2 BLANK...
Page 146: ...Technical Specification 2 1553 FGC 101 1014 Uen B B 20 BLANK...
Page 148: ...Static Parameters 2 1553 FGC 101 1014 Uen B C 2 BLANK...
Page 186: ...Redundancy Modes 2 1553 FGC 101 1014 Uen B E 2 BLANK...
Page 192: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 2 BLANK...
Page 196: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 6 Figure F 3 Editing Stack Download Ports...
Page 198: ...ProMPEG FEC Support for IP Streaming 2 1553 FGC 101 1014 Uen B G 2 BLANK...
Page 204: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 2 BLANK...
Page 212: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 10 BLANK...
Page 214: ...PSIG Support 2 1553 FGC 101 1014 Uen B I 2 BLANK...
Page 220: ...BISS Support 2 1553 FGC 101 1014 Uen B J 2 BLANK...