Operating the Multiplexer using nCompass Control
4.8.2.3
Set up a Secondary Output for the Transport Stream
The next step is to set up a secondary output for the transport stream. This cannot
go over the same physical port. In this configuration, the secondary output is
required to provide the feed to the Monitoring device. This has the same content as
that supplied as the primary output.
If required, more than one secondary output can be added for a single transport
stream.
Table 4.12 Setting Up a Multiplexer Secondary Output
Step Action
Result
Comments
1
In
nCompass, Profile Manager
, right
click on the required
Transport
Stream
Displays the
Transport
Stream
tabbed page
2
Select
Secondary Outputs
Displays the
Multiple
Outputs
dialog box
3
Select
Add/Remove
Displays a list of Available
and Selected outputs
4
Use the
Add
button to select the
required
Transport Streams
As each stream is selected, it
is added to the Selected
Outputs List.
Only outputs that can be
routed should populate
this list.
4.9
Set up PSI/SI Remultiplexing
4.9.1
Overview
This configuration removes user selected PSI/SI generated by nCompass Control
and the MX8400 Multiplexer and allows the operator to create a Private Data stream
with PSI/SI from an incoming transport stream
Figure 4.4 PSI/SI Remultiplexing
MX8400
Multiplexer
Transport Stream containing
selected PSI/SI from remote T
in addition to any required from
Local generation
S
TS OUT
REMOTE TS
LOCAL TSs
Remote sourced
PSI/SI
PSI/SI
Substitution
PSI/SI
Extraction
Local PSI/SI
Generation
2/1553-FGC 101 1014 Uen B
4-15
Summary of Contents for MX8400
Page 1: ...MX8400 Multiplexer Software Version 5 2 0 and later REFERENCE GUIDE 2 1553 FGC 101 1014 Uen B...
Page 26: ...Installing and Powering Up 2 1553 FGC 101 1014 Uen B 2 4 BLANK...
Page 94: ...Operating the Multiplexer using nCompass Control 2 1553 FGC 101 1014 Uen B 4 18 BLANK...
Page 96: ...Preventive Maintenance and Fault finding 2 1553 FGC 101 1014 Uen B 5 2 BLANK...
Page 146: ...Technical Specification 2 1553 FGC 101 1014 Uen B B 20 BLANK...
Page 148: ...Static Parameters 2 1553 FGC 101 1014 Uen B C 2 BLANK...
Page 186: ...Redundancy Modes 2 1553 FGC 101 1014 Uen B E 2 BLANK...
Page 192: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 2 BLANK...
Page 196: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 6 Figure F 3 Editing Stack Download Ports...
Page 198: ...ProMPEG FEC Support for IP Streaming 2 1553 FGC 101 1014 Uen B G 2 BLANK...
Page 204: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 2 BLANK...
Page 212: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 10 BLANK...
Page 214: ...PSIG Support 2 1553 FGC 101 1014 Uen B I 2 BLANK...
Page 220: ...BISS Support 2 1553 FGC 101 1014 Uen B J 2 BLANK...