Operation and Maintenance Support
Description
The Operational indicator is controlled from the Diagnostics and Fault
handling functionality, Restart and Recovery functionality and Function
Change Functionality. The indicator is turned off 2-10 seconds after the
SW has started. When the RU is reset in any way the handling of the
indicator is terminated.
For description of the Remote Operational Indication function and
Operational Information function see the parts of this section called
"Operational States" (part "RU in Remote Mode").
Colour:
Green
Position:
Main RUs (DXU, TRU, ECU) and Sub
RUs (PSU, BFU, CDU).
States of the indicator
ON:
The RU is considered Operational.
FLASHING (0.5 Hz):
−
Configuration activity initiated from the BSC,
(which may take more than 10 seconds to
complete) in progress OR
−
SW is being received OR
−
Restart pending (after SW download).
OFF
The RU is considered Not Operational.
Priority
FLASHING has a higher priority than ON
and OFF. ON has a higher priority than
OFF. If the conditions for two states are
fulfilled, the one with the highest priority
will control the indicator.
Operational States
EN/LZT 720 0008
P2A
2001-11-28
355 (485)
© Ericsson Radio Systems AB
— All Rights Reserved —
P
re
li
m
in
a
ry
Summary of Contents for RBS 2106