Operation and Maintenance Terminal
This function makes it possible for the operator to define (or
redefine) the IDB parameter RBS TF Compensation Value.
•
Display TF Compensation Value
The IDB parameter RBS TF Compensation Value (in ns) is
displayed.
The following user functions, related to the /G. 703/ 2048 kbit/s PCM
network, are available in the OMT:
•
Display spare bits, display spare bits in timeslot 0 on G.703,
values (0 or 1) for bits Sa4-Sa8.
•
Define spare bits (bits can be defined independently of each other).
•
Display CRC-4 (Cyclic Redundancy Check /G.704/), display
whether handling of CRC-4 in timeslot 0 on G.703 is on or off.
•
Switch on CRC-4.
•
Switch off CRC-4.
•
Monitor maintenance data, display PCM reference data and update
changes continuously.
•
Modify PCM Receiver Sensitivity
Sets the individual PCM Receiver Sensitivity values for an E1
transmission interface. The values are defined and referred as
parameters PCM-A-REC-SENS and PCM-B-REC-SENS in the
IDB.
Exception: A DXU which uses the PRACT transmission circuit
does not support the PCM Receiver Sensitivity values.
•
Display PCM Receiver Sensitivity
Displays the individual PCM Receiver Sensitivity values for an
E1 transmission interface. The values are defined and referred as
parameters PCM-A-REC-SENS and PCM-B-REC-SENS in the
IDB.
Exception: A DXU which uses the PRACT transmission circuit
does not support the PCM Receiver Sensitivity values.
The following user functions, related to the /DS1/ 1544 kbit/s PCM
network, are available in the OMT:
•
Modify LBO values for transmission interface.
Sets the individual LBO values for a T1 transmission interface.
The values are defined and referred as parameters LBO-A and
LBO-B in the IDB.
Exception: A DXU which uses the PRACT transmission circuit
does not support the LBO values.
•
Display LBO values for transmission interface.
Displays the individual LBO values for a T1 transmission
interface. The values are defined and stored as parameters LBO-A
and LBO-B in the IDB.
EN/LZT 720 0008
P2A
2001-11-28
389 (485)
© Ericsson Radio Systems AB
— All Rights Reserved —
P
re
li
m
in
a
ry
Summary of Contents for RBS 2106