EMC Capabilities
Table 165
Magnetic field emission
Limit standard
VDE 0878, Magnetic emission, part 1
Limit
Class B
52.3.4
Conducted Immunity on AC Input Power Ports
Table 166
Fast transient test
Basic standard
EN 61000-4-4
Test level
4 kV common mode between all lines and cabinet ground reference
Performance
Criteria B
Limit standard
ETS 300 342-2
Test level
4 kV common mode between all lines and cabinet ground reference
Performance
Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 167
Surge test
Limit standard
ETS 300 342-2
Test level
2 kV common mode between all lines and cabinet ground
reference
1)
1 kV differential mode, between line and line
Performance
Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
1)
System primary protected
Table 168
RF common mode test
Limit standard
ETS 300 342-2
Test level
10 V(rms)
Performance
Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
Table 169
Voltage dips and interruptions on AC ports
Basic standard
EN 61000-4-11
Performance
Criteria A for a complete system
EN/LZT 720 0008
P2A
2001-11-28
407 (485)
© Ericsson Radio Systems AB
— All Rights Reserved —