Hardware Control and Troubleshooting
Table 46
Output Fields for the show port Command with the detail Keyword
Field
Value/Description
Clock Source
(1)
State of source of the transmit clock:
global-reference—system clock on the active controller card.
(2)
local—local clock located on the line card (onboard clock).
(3)
loop—receive clock derived from the incoming signl on the port.
card-reference—clock source that has been specified for the line cards.
Crc
Configured value of the cyclic redundancy check for a SONET/SDH port (16 or 32).
Dampening Count
n
—Number of instances this link-dampened port went down and came up within the limits set by
the
link-dampening
command. This count is reset only when the port is removed from the
configuration with the
no
form of the
port
command (in ATM OC or port configuration mode).
Description
Configured description.
Diag Monitor
• No—SFP cannot monitor its faults nor report power readings
• Yes—SFP can monitor its faults and report power readings
DSU Bandwidth
nn.nn
Mbps—Bandwidth of configured data service unit (DSU).
DSU Mode
digital-link
—Configured vendor of DSU.
DSU Scramble
DSU scramble condition (on or off).
Duplex Mode
• full—Port condition, Ethernet or Gigabit Ethernet (any version).
• half—Port condition,10/100 Ethernet only.
Encapsulation
The encapsulation for this port:
• 802.1q
• atm
• cisco-hdlc
• ethernet
• frame-relay
• ppp
FEAC code received
Far end alarm condition (of the remote system):
• Service affecting (SA) equipment failed.
• Nonservice affecting (NSA) equipment failed.
• Common equipment failed.
• N/A or NONE—No alarm condition received.
Flow control
Condition of flow control for Gigabit Ethernet port, any version, (on or off).
Framing
Configured framing for the port:
• c-bit
• g751
• m23
• ESF
• SF
• sdh (an option of ATM OC, POS, and WAN-PHY ports)
• sonet (an option of ATM OC, POS, and WAN-PHY ports)
65
27/153 30-CRA 119 1170/1 Uen A
|
2010-04-09
Summary of Contents for SmartEdge 600
Page 1: ...SmartEdge 600 Router Hardware Guide Release 6 3 INSTALLATION 27 153 30 CRA 119 1170 1 Uen A ...
Page 6: ...SmartEdge 600 Router Hardware Guide 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Page 26: ...SmartEdge 600 Router Hardware Guide 20 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Page 108: ...SmartEdge 600 Router Hardware Guide 102 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Page 112: ...SmartEdge 600 Router Hardware Guide 106 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...