background image

Installation & Operation Manual

                                                        

 

 

 

 

 

 

 

 

 

 

Proven Quality since 1892

 

 

ECON check valves Fig. 2630-2631                    

                                                          www.eriks.com                                    

Rev. 0

 

                                                     

 

 

Content 

1.  ERIKS operating companies 
2.  Product description 
3.  Requirements for maintenance staff 
4.  Transport and storage 
5.  Function 
6.  Application 
7.  Installation 
8.  Maintenance 
9.  Service and repair 
10. Troubleshooting 
11. Removal 

 

1.  ERIKS operating companies 

ECON ball check valves are being delivered by several ERIKS operating companies on a 
worldwide basis. In this manual these will be referred to as ‘ERIKS’, the individual terms of 
delivery of the ERIKS operating company having executed the order are applicable. 

 

2.  Product description 

The ECON ball check valves are designed according to the information in our latest catalogue or 
see our websit

www.eriks.com

 and should be used in accordance with the applicable pressure-

temperature rating as stated on this website. ECON ball check valves are provided with casted 
markings according to EN 19. The marking makes the identification of the valve easier and 
contains: 

size (DN) 

pressure rating class  

body material marking 

arrow, indicating the medium flow direction 

ECON logo 

 

3.  Requirements for maintenance staff 

The staff assigned to assembly, operating and maintenance tasks should be qualified to carry out 
such jobs and in any circumstance, ensure personal safety  

 

4.  Transport and storage 

Transport and storage should always the valve should be protected against external forces, 
influence and destruction of the painting layer as well. The purpose of the painting layer is to 
protect the valve against rust, during transport and storage. The valves should be stored in an 
unpolluted space and should also be protected against all atmospheric circumstances. There 
should be taken care of the temperature and humidity in the room, in order to prevent condensate 
formation. 

 

5.  Function 

ECON ball check valves are designed for the prevention of flow reversal. The operation of the 
valve is fully automatic allowing liquid to flow in one direction only. The flowing medium presses 
against the ball, thereby push them open. The ball check valve can be installed horizontal and 
vertical (upward flow). 

 
6.  Application 

ECON ball check valves use primarily in water purification stations, sewage treatment 
installations, water supply facilities, pumping stations, etc. Application: for clean, waste and 
sewage water and viscous media. The operation of the valve is fully automatic allowing liquid to 
flow in one direction only. The installation designer is responsible for the check valve selection, 
suitable for the working conditions. The valves are unsuitable, without written permission of an 
ERIKS company, to apply for hazardous media as referred into Regulation (EC) No 1272/2008. 

 

Summary of Contents for ECON Series

Page 1: ...arry out such jobs and in any circumstance ensure personal safety 4 Transport and storage Transport and storage should always the valve should be protected against external forces influence and destruction of the painting layer as well The purpose of the painting layer is to protect the valve against rust during transport and storage The valves should be stored in an unpolluted space and should al...

Page 2: ...e correct flange size must be used In horizontal pipelines the valve must be installed so that the bolted cover is facing upward for version with sinking ball The valve must be installed with the direction arrow on the body coincident with the direction of flow in the pipeline For vertical pipelines the flow direction should only be upwards Immediately prior to valve installation the pipeline shou...

Page 3: ...ore starting any service jobs make sure that the medium supply to the pipeline is cut off pressure was decreased to ambient pressure the pipeline is completely cleaned and ventilated and the plant is cooled down Always keep safety instructions in mind and take all personal safety precautions ECON ball check valves do not require any special maintenance In certain cases it might be possible to repl...

Page 4: ...test should be carried out after installation the valve should be checked and maintained periodically at least every 3 months depending on the medium Replacement and or cleaning of ball check valve components Loosen the bolts of the bonnet 5 in a cross sequence and with correct tools in order to avoid damage to the components Proceed by lifting the bonnet For big sizes it is recommended to use ele...

Page 5: ...the bonnet 2 centered correctly in the opening of the body 1 take special care that the O ring is placed in correct position in order to avoid damage when fixing the bolts Finally start fixing the bolts 5 in a cross sequenced order 10 Troubleshooting It is essential that the safety regulations are observed when identifying the fault Problem Possible cause Corrective measures No flow Valve is insta...

Page 6: ...unifer large potential differences may occur possibly causing corrosion which could permanently damage the proper functioning and integrity of our product A combination of different materials should always be mentioned prior to the purchase of our products in order for us to give the best possible advise on a safe functioning General note for cast iron products Cast iron can be used for various ap...