10.  Service and repair 

All service and repair jobs should be carried out by authorized staff, using suitable tools and user 
shall use genuine valve parts. 

welding repair and drilling of the Sample Coolers is forbidden.  

it is forbidden to replace the bolt, nut or packing when the Sample Coolers is under 
pressure. 

There are no spare parts available for the ECON Sample Coolers. 

  

11.  Safety notes 

Allow time for temperature to normalize after isolation to avoid danger of burns. 

 

12.  Troubleshooting 

It is essential that the safety regulations are observed when identifying the fault. 

 

13.  Removal 

Dismantled and rejected valves cannot be disposed with household waste. The Sample Coolers 
are made of materials which can be re-used and should be delivered to designated recycling 
centres. 

 

Summary of Contents for econ

Page 1: ...manual these will be referred to as ERIKS the individual terms of delivery of the ERIKS operating company having executed the order are applicable 2 Product description The ECON Sample Coolers are designed according the information on our website www eriks com and should be used in accordance with the applicable pressure temperature rating as stated on this website Sample Coolers are provided with...

Page 2: ...itable The installation designer is responsible for the Sample Coolers selection suitable for the working conditions The Sample Coolers are unsuitable without written permission of an ERIKS company to apply for hazardous media as referred into Regulation EC No 1272 2008 7 Installation During the assembly of the Sample Coolers the following rules should be observed make sure before assembly that th...

Page 3: ... and ventilated and the plant is cooled down Always keep safety instructions in mind and take all personal safety precautions During maintenance the following rules should be observed always keep personal safety precautions in mind and always use appropriate protection e g clothing masks gloves etc be alert that the temperature still can be very high or low and can cause burns there are no interna...

Page 4: ...o replace the bolt nut or packing when the Sample Coolers is under pressure There are no spare parts available for the ECON Sample Coolers 11 Safety notes Allow time for temperature to normalize after isolation to avoid danger of burns 12 Troubleshooting It is essential that the safety regulations are observed when identifying the fault 13 Removal Dismantled and rejected valves cannot be disposed ...