# VSH400PLC090909
- 20 -
Fig.24
For SH400PLC PLATINUM there is an option of active measurement and rail
overbending to the desired angle.
8.3 OFFSETTING
Prepare the station as described in 6.1
Equip the station with offsetting inserts [4] and enter the settings as described
in item 6.5
Move the rail into the bending space and move the rail to the bumper S2
Set the offsetting value with a knob, Fig. 25.
Press the pedal Q3 to start the offsetting procedure; after the operation is
complete, the piston rod will return to its starting position.
To repeat the operation, release the pedal and press it again.
Note: Offestting process should be run only within the cylindrical elements of
the insertion. Do not press rails on the flat part of the insertion.
pole odkładcze
waste container
busbar
body