8 | Troubleshooting
Erme AG
44 / 51
Sous vide basins
8.2 Instructions on troubleshooting
NOTE
If the measures listed here do not rectify the fault, contact the
customer service department of the company ERME AG.
See chapter "Customer service".
8.3 Fault displays
The following error messages may be shown on the display and/or indicated by a
warning sound:
Error message
Possible causes
Remedy
"OverVolt" display and
acoustic signals
Overvoltage was detected.
Make sure that the voltage is in the
permissible range.
Acknowledge the error message and switch
the unit on and off again.
If the error continues to occur, contact the
customer service department of ERME AG.
Fans have failed.
"TempSens" display and
acoustic signals
Water temperature sensor is defective. Contact the customer service department of
ERME AG.
"OverCur" display and
acoustic signals for 4
seconds
Overcurrent was detected.
Acknowledge the error message and switch
the unit on and off again.
If the error is still displayed, contact the
customer service department of ERME AG.
"OverTemp" display and
acoustic signals
Overtemperature was detected.
Make sure that the requirements for the
installation site are satisfied.
Switch off the unit, let it cool down and
switch it back on.
"No water" display and
acoustic signals for 4
seconds
No water is filled in the unit or the
water level is too low.
Acknowledge the error message and add
water.
"Surge" display and acoustic
signals for 4 seconds
Short voltage surges were detected.
The heating is temporarily interrupted and is
automatically preset again.