10.5 Maintenance report
Perform the following maintenance work on the machine:
Work to be performed
Interval
Additional information
Perform a visual inspection of the machine for:
– Contamination
– Damage
Before starting up the
machine each time
Check the electrical connections and mains cable for
damage.
Before starting up the
machine each time
Have the identified defects
corrected immediately.
Check the pneumatic system for damage
Before starting up the
machine each time
For machines with inert gas.
Have the identified defects
corrected immediately.
Clean the machine.
After each use
See chapter
.
Clean sealing bar and Teflon strip
After each use
In case of wear, have the Teflon
strip replaced by the ERME
customer service department.
Run the service program.
Monthly
See chapter
.
Check the oil level.
Monthly
See chapter
.
Clean the piston rods.
Monthly
Clean the separator
As necessary
For machines equipped with the
GreenVac option, see