Use and maintenance manual
Auto-Puncher for timing belts
Model: APTM-600
__________________________________________________________________________________________________________________________________________________________________________
P a g 3 0
ERM ENGINEERING DC-1500 AUTOPUNCHER
N
L
230VAC
24VDC POWER SUPPLY
48VDC POWER SUPPLY
24VDC POWER SUPPLY
+48VDC
GND
EN-
EN+
DIR-
DIR+
CP-/CW-
CP+/CW+
ST
E
P
M
O
TO
R
D
R
IV
E
R
B-
B+
A-
A+
FIN
ZE
R
O
DOOR
EN
DIR
CP
G
ND
+24
EM
ER
PI
S
A
C
IL
I
EV
C
I
G
ND
+24
G
ND
+2
4V
D
C
+2
4V
D
C
G
ND
G
ND
+4
8V
D
C
L
L
N
N
5 +24VDC ELECTROVALVE
4 B- MOTOR
3 B+ MOTOR
2 A- MOTOR
1 A+ MOTOR
13 REED CILINDER/ REED CILINDRO
12 END SWITCH/ MICRORRUPTOR FINAL CARRERA
11 ZERO SWITCH/ MICRORRUPTOR INICIO CARRERA
10 DOOR SWITCH/ MICRORRUPTOR PUERTA
9 NOT CONNECTED/ NO CONECTADO
8 GND
7 +24VDC SWITCH COMMON/ COMUN MICRORRUPTORES
6 ELECTROVALVE
16 NOT CONNECTED/ NO CONECTADO
15 TWO SERIAL EMERGENCY STOP/ 2 PAROS EMERGENCIA EN SERIE
14 HOLDER/ BARRA PISADOR PRESOSTATO