START UP AND PROGRAMMING
DINGO operator for sliding gates
57
Advanced Functions Programming (D1= “
A
”)
1
Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2
Press the buttons ^ and
V
until D1 shows the letter
A
flashing. Press ENTER to confirm. D2 flashes.
3
Press the buttons ^ and
V
until the required D2
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4
Press the buttons ^ and
V
until the required D3 and
D4 value appears (see chart). Press ENTER to
confirm.
5
Press ESC to return to the previous display.
D1
D2
Parameter
D3
D4
D e f a u l t
option
Options or values
A
0
Flashing light
0
1
x
No pre-warning
0
2
With pre-warning
1
Garage light time
0
3
x
3 sec.
0...5. 0...9
59
= 59 sec.;
2.5
= 2 min. 50 sec., etc
2
Gate speed
0
1...5
03
01
: minimum speed;
05
: maximum speed
3
Slowdown speed
0
1...5
03
01
: minimum speed;
05
: maximum speed
4
Slowdown distance
0
0...5
03
00
: minimum distance;
05
: maximum
distance
5
Reverse after closing (to offset
the expansion of the gate)
A50x
: Stops in the selected
p o s i t i o n w i t h o u t m a k i n g
contact
A51x
: Makes contact and
reverses back to the selected
position
0...1
0...9
04
x0
: no reverse;
x9
: maximum reverse
6
Maximum force
0
8
x
0...1
0...9
01
: minimum force;
10
: maximum force
7
Closing
photocell
used during
standby (in automatic mode
only)
0
1
Immediate closing
0
2
x
Restart standby time
0
3
Has no effect
8
Pushbutton
operation
during
standby (in automatic mode
only)
0
1
Immediate closing
0
2
x
Restart standby time
0
3
Has no effect
9
Opening mode
0
1
x
Opening in accordance with the mode
selected in the main functions (
F
)
0
2
Collective opening
(the control board does not obey the key
commands during opening)
0
3
Step-by-step opening
(the gate stops if a key device is activated
during opening. The gate closes when
operated again)