Photocell connection
Photocells ensure that the leaves do not trap anyone when closing by stopping the door and opening it inmediately, if
any obstacle is detected in the leaves´closing lines. The door will remain in “open door” if the photocell detects any
person or obstacle.
- Connections:
- Photocell setup
The photocells that are installed have a test input to monitor and ensure there are working properly. Therefore, by
default, the input should be set up “with test” mode. Before every closing cycle the control board will check the
photocell to ensure it is working correctly.
Nevertheless, the operator is able work with photocells that do not have a test setting input. In that case photocells
should be set by digital selector “without test”.
To access the “Technical menu”: Press the following 3
buttons during a 1 second duration: Door open, door
close and winter.
,
,