Automatic swing door PREMIS 200
35
INSTALLATION - ELECTRICAL
Programmable input - FIRE DOOR
The smoke detection device (or activation signal) must
be installed in doors configured as Fire Doors. Reset to
restart the door.
When selecting the type of door as fire door,
input 2 will be automatically configured as fire
door function activation and the signal will be
normally open.
Programmable input - HOLD OPEN
A programmable input can be configured to keep the
door open using the hold-open devices.
In this case, the door is only kept open by the action of
the device; the motor is released.
A programmable output (PO1 or PO2) must be
configured to activate the electromagnet to hold the
door open.
Connections
diagram
FIRE PROTECTION
DEVICE
25 26 27
PI2 PI1 +24
HOLD OPEN
ACTIVATION
ELECTROMAGNET
SUPPLY
(DOOR OPEN)
+
-
28 29 30 31
PO2
COM
PO2
NO
PO1
COM
PO1
NO
ELECTROMAGNET
(DOOR OPEN)
+
-
Connections diagram
1.- Activation
2.- Electromagnet (Open Door)