background image

10

  

R.E.

(ST1)

(ST2)

(DIP6=OFF: FCA)

(DIP6=ON: FCC)

FC1

(DIP6=OFF: FCC

(DIP6=ON: FCA)

FC2

P268Y

DL1 DL2 DL3

ST1

ST2

SW1

DL6

F1-0,315A

SW2

F5-3A

F6-0,5A

ST

1

FT

1

ST

2

FT

2

+12
GND

ST

O

P

LAMP

G2

G1

C

N

L

MO
TOR

PO
WER

(FT1)

SG. A

 (FT2)

RADIO

RECEIVER

DL21

DL8

W

aiting

Time

PO
T2

DL11

DL7

DL9

DL10

(12Vdc)

G2
G1

C

DL26

General connections

DIP6=OFF

DIP6=ON

Check and configure turning direction and limit switches

Encoder (DIP7): 

for the correct operation of the encoder, ensure DIP7 is in ON. The operation needs to be

reprogrammed if the encoder is disabled.
Check that DL21 flashes during gate movement.

A capacitor should not be used for the motor with the PUMA-I
operator fitted with Inverter technology control board.

DL1

Automatic closing LED

DL2

Radio programming LED

DL3

Travel programming LED 

DL6

FT2 photocell LED

DL7

FC1 limit switch LED

DL8

FC2 limit switch LED

DL9

FT1 photocell LED

DL10

ST2 pushbutton LED

DL11

ST1 pushbutton LED

DL21

Encoder LED

DL26

DC Bus LED 

Motor with

no capacitor

Turning direction:

 check operation using ST1 and ST2 mini-pushbuttons with DIP1=ON. If turning direction is not as

indicated for position DIP6, interchange the wires connected to the G1 and G2 terminals.

PEDESTRIAN

TOTAL

E268L

SW1

SW1 Functions during programming (DIP1=ON)

DIP1=ON

: programming enabled (DL3 lights up); ST1: open, ST2: close

DIP1=ON and DIP2=ON

: total open/close programming

DIP1=ON and DIP3=ON

: pedestrian open/close programming

DIP1=ON and DIP4=ON

: total opening radio code programming

DIP1=ON and DIP6=ON

: pedestrian opening radio code programming

Reviews: