10
R.E.
(ST1)
(ST2)
(DIP6=OFF: FCA)
(DIP6=ON: FCC)
FC1
(DIP6=OFF: FCC
(DIP6=ON: FCA)
FC2
P268Y
DL1 DL2 DL3
ST1
ST2
SW1
DL6
F1-0,315A
SW2
F5-3A
F6-0,5A
ST
1
FT
1
ST
2
FT
2
+12
GND
ST
O
P
LAMP
G2
G1
C
N
L
MO
TOR
PO
WER
(FT1)
SG. A
(FT2)
RADIO
RECEIVER
DL21
DL8
W
aiting
Time
PO
T2
DL11
DL7
DL9
DL10
(12Vdc)
G2
G1
C
DL26
General connections
DIP6=OFF
DIP6=ON
Check and configure turning direction and limit switches
Encoder (DIP7):
for the correct operation of the encoder, ensure DIP7 is in ON. The operation needs to be
reprogrammed if the encoder is disabled.
Check that DL21 flashes during gate movement.
‹
A capacitor should not be used for the motor with the PUMA-I
operator fitted with Inverter technology control board.
DL1
Automatic closing LED
DL2
Radio programming LED
DL3
Travel programming LED
DL6
FT2 photocell LED
DL7
FC1 limit switch LED
DL8
FC2 limit switch LED
DL9
FT1 photocell LED
DL10
ST2 pushbutton LED
DL11
ST1 pushbutton LED
DL21
Encoder LED
DL26
DC Bus LED
‹
Motor with
no capacitor
Turning direction:
check operation using ST1 and ST2 mini-pushbuttons with DIP1=ON. If turning direction is not as
indicated for position DIP6, interchange the wires connected to the G1 and G2 terminals.
PEDESTRIAN
TOTAL
E268L
SW1
SW1 Functions during programming (DIP1=ON)
DIP1=ON
: programming enabled (DL3 lights up); ST1: open, ST2: close
DIP1=ON and DIP2=ON
: total open/close programming
DIP1=ON and DIP3=ON
: pedestrian open/close programming
DIP1=ON and DIP4=ON
: total opening radio code programming
DIP1=ON and DIP6=ON
: pedestrian opening radio code programming