i-CON 1 / 4
3BA00180 • 8.04.008 • Rev. 1
Operating instructions
Code
Test in display
Cause
Remedy
[CALIBRATION FATAL ER-
ROR !]
Station no longer calibrated
Have factory calibration car-
ried out
4
[RT-compensation]
Measurement reading of KTY
not ok
Have soldering tool and sol-
dering station checked
7
[HE MISSING ? SENSOR ?]
Heating element is not in-
stalled correctly
Thermocouple error
Install heating element cor-
rectly
Have soldering tool checked
8
[HEAT ELEMENT?]
Heater defect
Check heating element /
Check soldering station
9
[DATA LOST!]
Parameter/Configuration data
destroyed
Reset soldering station to fac-
tory setting in the configura
-
tion mode
71
[iTOOL AND HE DEFECTIVE/
EXCHANGE]
Both the electronics and the
heating element of the i-Tool
are defective.
Replace the i-Tool
98
[MAINS FREQUENCY ER-
ROR]
Mains frequency outside of
frequency range (± 10%)
-
99
[iCON OVERLOAD PRO-
TECTION]
Soldering station overloaded
Allow the soldering station to
cool down