9
3BA00253-01
•
2021-05-17
•
Rev. 1
Ersa i-CON 1V & i-CON 1VC
4.4
Contrast
To adjust the contrast on the display to the single working
environments, proceed as follows:
■
Switch on the station and immediately turn the i-OP.
This will enable the contrast mode:
The buzzer signals with a beep sound that the contrast mode is active.
■
Set the desired contrast by turning the i-OP.
■
Confirm your entry by pressing the i-OP.
5.
Editing parameters
To edit the value of a parameter, proceed as follows:
■
Activate the soldering tool whose parameters are to
be edited by pressing the i-OP.
■
Press the i-OP and hold it for approx. 2 seconds.
■
Select the desired parameter by turning the i-OP.
■
Activate the cursor by pressing the i-OP; pressing it
again will switch the cursor back off.
When the cursor is activated, the value of the parameter can be changed accordingly by
turning the i-OP.
2
0
_
1
0
_
1
0
_
0
2 s
1
0
_
♪!
2
♪!
0
2s
0
0,5 s
3
0
_
2
0
_
Editing parameters