installation
31
input terminal BoarD
230/460 Vac moDels
200 VAC CONFIGURATION
Jumper Wire
input terminal BoarD
230/460 Vac moDels
400 VAC CONFIGURATION
Jumper Wire
note:
Wires connected on 230/460 main transformer tap must
be re-connected to 200/400 main transformer tap on all
3 coils. Be sure to replace insulating vinyl covering over
connections.
1 2 3 4 5 6 7 8 9 10 11
12
1 2 3 4 5 6 7 8 9 10 11
12
1 2 3 4 5 6 7 8 9 10 11
12
1 2 3 4 5 6 7 8 9 10 11
12
tB2
JUMPER POSITIONS FOR 230/460 VAC
tB2
JUMPER POSITIONS FOR 200/400 VAC
1 2 3 4 5 6 7 8 9 10 11
12
1 2 3 4 5 6 7 8 9 10 11
12
note:
TB2 wires connected on 230/460 must be re-
connected to 200/400.
230/460 tap
200/400 tap