installation
33
1 2 3 4 5 6 7 8 9 10 11
12
1 2 3 4 5 6 7 8 9 10 11
12
tB2
JUMPER POSITIONS FOR 380 VAC
1 2 3 4 5 6 7 8 9 10 11
12
1 2 3 4 5 6 7 8 9 10 11
12
400 tap
380 Vac and 400 Vac models
(continued) -
2. Reconfigure TB2 terminal strip for proper voltage.
tB2
JUMPER POSITIONS FOR 400 VAC
1 2 3 4 5 6 7 8 9 10 11
12
1 2 3 4 5 6 7 8 9 10 11
12
3. Reconfigure secondary taps on all three main transformer
coils. A removable service panel is located above the transform-
er connections to improve access.
Access Panel
380 tap
note:
Wires connected on main transformer tap must
be re-connected to 400 or 380 main transformer
taps on all 3 coils. Be sure to replace insulating vinyl
covering over connections.
575 Vac models
- this model is not configurable to any other
input voltage.
Summary of Contents for 0558011310
Page 2: ...EPP 202 Plasma Power Source 2...
Page 4: ...EPP 202 Plasma Power Source 4...
Page 7: ...SAFETY...
Page 8: ...SAFETY 8...
Page 21: ...DESCRIPTION...
Page 22: ...description 22...
Page 25: ...INSTALLATION...
Page 26: ...installation 26...
Page 39: ...installation 39 J1 RAS Interface Cable CAN Cables...
Page 40: ...installation 40...
Page 41: ...OPERATION...
Page 42: ...OPERATION 42...
Page 50: ...OPERATION 50...
Page 51: ...MAINTENANCE...
Page 52: ...Maintenance 52...
Page 57: ...TROUBLESHOOTING...
Page 58: ...58 TROUBLESHOOTING 58...
Page 65: ...REPLACEMENT PARTS...
Page 66: ...Replacement Parts 66...
Page 68: ...Replacement Parts 68...
Page 69: ...revision history 1 Originally released 01 2015 2 Revision 10 2015 added RotorFlow Sensor...