SLICE EXOTHERMIC CUTTING EQUIPMENT
9
89250840
Art # A-13638
FAULT CHARGING CHARGED
STRIKER
TEST
TORCH
DC IN 22-30V
Cam Lock Female
Terminal F/ Torch
Cam Lock Female
Terminal F/ Striker
Test Button
DC Input
Fault / Charge Status Gauge
CAUTION
THIS UNIT CONTAINS A LEAD ACID BATTERY WHICH RELEASES EXPLOSIVE
HYDROGEN GAS WHEN BEING CHARGED. CHARGE THIS BATTERY ONLY IN A
VENTILATED LOCATION DESIGNATED AS A LEAD-ACID BATTERY CHARGING
AREA. DO NOT CHARGE THIS BATTERY WHILE OPERATING THIS TORCH.
Figure 3: SLICE Battery Ignition Source
4.06 Charging the Ignition Source
There are 3 LEDs on the Ignition Source panel (FAULT, CHARGING, and CHARGED). Fully charged
status will display all LEDs green. For explanation of LED readouts refer to Section 9.2 Ignition Source
LED Display Guide. The AC/DC Power Adapter (p/n 96-076-043) is required to complete these steps.
NOTE!
It is recommended that the unit be recharged after every use or when-
ever the Charge Status LEDs shows 50% or less.
Charging the Ignition Source:
1. Press the TEST button on the Ignition Source panel to check status. If the LEDs do not present
all green LEDs then proceed with the steps below.
2. Insert the AC/DC Power Adapter Output connector into the DC Input socket on the Ignition Source
panel and plug the Power Adapter input cord into a 120 V, 60Hz or 240 V 50Hz wall outlet.
3. Keep the unit plugged in until fully charged. Charging time can be between 2-5 hours. On the
Ignition Source panel amber LEDs will display when fully charged.
4. Disconnect the AC/DC Power Adapter connector from the Ignition Source and push the Test
button to confirm full charge status. All the LEDs will display green.