9 CONFIGURATION MENU
0460 896 274
- 54 -
© ESAB AB 2013
9.3.2
4-stroke configuration
In 4-stroke configuration, various functions of 4-stroke start and stop can arise.
4-stroke start setting
•
Trigger-controlled gas pre-flow, see the “4-stroke” section.
•
Time-controlled gas pre-flow.
A = Gas flow
B = Wire feed
C = Gas pre-flow
D = Welding
Press in the trigger switch (1), gas pre-flow starts; after the set gas pre-flow time, the
welding process starts. Release the trigger switch (2).
•
Trigger-controlled hot start
A = Gas flow
B = Wire feed
C = Gas pre-flow
D = Hot start
E = Welding
Press in the trigger switch (1); gas pre-flow starts and hot start runs until the switch is
released (2).
4-stroke stop setting
•
Time-controlled crater filling with possible extension, see the "4-stroke" section.
•
Trigger controlled crater filling time
A = Gas flow
B = Wire feed
C = Welding
D = Crater filling
Press in the trigger switch (3); crater filling commences and expires. If the trigger switch is
released (4) within the crater filling time (crater filling time shortened), welding is interrupted.
Summary of Contents for Aristo U82
Page 1: ...Aristo Instruction manual 0460 896 274 GB 20130902 Valid from program version 1 15A U82 ...
Page 80: ...MENU STRUCTURE 0460 896 274 80 ESAB AB 2013 MENU STRUCTURE ...
Page 81: ...MENU STRUCTURE 0460 896 274 81 ESAB AB 2013 ...
Page 82: ...MENU STRUCTURE 0460 896 274 82 ESAB AB 2013 ...
Page 83: ...MENU STRUCTURE 0460 896 274 83 ESAB AB 2013 ...
Page 84: ...MENU STRUCTURE 0460 896 274 84 ESAB AB 2013 ...