9 CONFIGURATION MENU
0460 896 274
- 56 -
© ESAB AB 2013
9.3.4
Voltage measurement in pulsing
Options for voltage methods in pulsing are as follows:
•
Peak value in pulse voltage PULSE The voltage is measured only during the pulse
section and filtered before the voltage value is presented on the display.
•
Voltage average value AVERAGE
The voltage is measured continuously and filtered before the voltage value is presented.
The measurement values that are presented on the display are used as input data for
internal and external quality functions.
9.3.5
AVC feeder
When you have connected an AVC wire feed unit (ARC VOLTAGE CONTROL), go into the
CONFIGURATION menu under MIG/MAG BASIC SETTINGS. Press ENTER at the AVC wire
feed unit row and select ON. The equipment is then reconfigured automatically to match an
AVC wire feed unit.
9.3.6
Release pulse
If the wire becomes trapped in the workpiece, the system detects this. A current pulse is
sent out that releases the wire from the surface.
In order to obtain this function, select RELEASE PULSE in the list under MIG/MAG BASIC
SETTINGS, then press ENTER and select ON.
9.4
MMA defaults
Main menu → Configuration menu → MMA defaults
Drop welding
Drop welding can be used when welding with stainless electrodes. The function involves
alternately striking and extinguishing the arc in order to achieve better control of the supply of
heat. The electrode needs only to be raised slightly to extinguish the arc.
Here you can select ON or OFF.
9.5
Fast mode soft keys
The soft keys WELD DATA 1 to WELD DATA 4 are displayed in the fast mode menu. These
are configured as follows:
Position the cursor on the SOFT KEY NUMBER row.
Summary of Contents for Aristo U82
Page 1: ...Aristo Instruction manual 0460 896 274 GB 20130902 Valid from program version 1 15A U82 ...
Page 80: ...MENU STRUCTURE 0460 896 274 80 ESAB AB 2013 MENU STRUCTURE ...
Page 81: ...MENU STRUCTURE 0460 896 274 81 ESAB AB 2013 ...
Page 82: ...MENU STRUCTURE 0460 896 274 82 ESAB AB 2013 ...
Page 83: ...MENU STRUCTURE 0460 896 274 83 ESAB AB 2013 ...
Page 84: ...MENU STRUCTURE 0460 896 274 84 ESAB AB 2013 ...