9 CONFIGURATION MENU
0460 896 274
- 59 -
© ESAB AB 2013
Select the numbers for the memories where current weld data is stored using the plus/minus
knobs and then press STORE.
The SELECTED WELD DATA row shows which weld data have been selected and in what
order they occur, from left to right. The weld data set for the most recently selected position is
displayed under the line in the display.
To remove weld data, follow the same procedure as above but press the DELETE key.
9.11
Multiple wire feeders
Main menu → Configuration menu → Multiple wire feeders
When connecting several wire feed units (max. 4), you have to use wire feed units without a
weld data unit, i.e. with an empty panel.
All wire feed units that are supplied to the customer have identity number 1.
The first thing you have to do when connecting several wire feed units is to change the
identity number (node address) of one wire feed unit.
To change the ID number, proceed as follows:
•
Connect the first wire feed unit, go to the MULTIPLE WIRE FEEDERS menu.
•
Press and release the trigger switch to activate the wire feed unit.
•
Then read on the first row which ID number the wire feed unit has (should be 1 the first
time). Then select a new ID number between 2 and 4.
Position the cursor on the SELECT A NEW ID NUMBER row. Set the desired number
between 1 and 4 by stepping with the plus/minus knobs. Press ENTER.
On the top row, the figure for the ID number will change to the desired number.
•
Connect the next wire feed unit.
•
Press and release the trigger switch to activate this wire feed unit. You can now see that
the unit has ID number 1.
Configuration is now complete and you can start using the equipment as normal. In the same
way it is possible to configure and run four wire feed units. The important thing when using
several wire feed units is not which ID number they have been given, but that they are given
different numbers in order that they can be distinguished.
Take care not to give the same ID to two wire feed units. If this should occur, rectify the
situation by disconnecting one of the units and then starting the above procedure again from
Summary of Contents for Aristo U82
Page 1: ...Aristo Instruction manual 0460 896 274 GB 20130902 Valid from program version 1 15A U82 ...
Page 80: ...MENU STRUCTURE 0460 896 274 80 ESAB AB 2013 MENU STRUCTURE ...
Page 81: ...MENU STRUCTURE 0460 896 274 81 ESAB AB 2013 ...
Page 82: ...MENU STRUCTURE 0460 896 274 82 ESAB AB 2013 ...
Page 83: ...MENU STRUCTURE 0460 896 274 83 ESAB AB 2013 ...
Page 84: ...MENU STRUCTURE 0460 896 274 84 ESAB AB 2013 ...